Aspen Pumps Silent+ MINI ORANGE Manual De Instrucciones
Aspen Pumps Silent+ MINI ORANGE Manual De Instrucciones

Aspen Pumps Silent+ MINI ORANGE Manual De Instrucciones

Ocultar thumbs Ver también para Silent+ MINI ORANGE:

Enlaces rápidos

40531-silent-plus orange-manual-0416.indd 1
04/05/2016 14:36
loading

Resumen de contenidos para Aspen Pumps Silent+ MINI ORANGE

  • Página 1 40531-silent-plus orange-manual-0416.indd 1 04/05/2016 14:36...
  • Página 2 5/8” / 16mm o/d (x 2) 140 x 3.6mm / 5.5” x 1/8” (x 4) 300 x 3.6mm / 12” x 1/8” Aspen Pumps, Apex Way, Hailsham, East Sussex, BN27 3WA, UK, +44 (0)1323 848842, [email protected] 40531-silent-plus orange-manual-0416.indd 2-3 04/05/2016 14:36...
  • Página 3 • CAUTION: This Aspen pump has been • ATTENTION : Cette pompe Aspen a été conçue • ATTENZIONE: La pompa Aspen è stata ВНИМАНИЕ!: Данный насос производства Aspen • evaluated for use with water only. pour un usage à l’eau exclusivement. progettata per il solo impiego con acqua.
  • Página 4 • Pump rating 115V / 230V AC: 50/60Hz 0.1A • Caractéristiques électriques 115 V / 230 V CA : • Pumpenauslegung 115 / 230 V AC: 20 W, 50/60 Hz 0.1A • Características eléctricas: 115 / 230 V CA, 50/60Hz 0.1A • Tensione nominale pompa: 115 V / 230 V CA, 50/60Hz 0.1A • Max. water flow rate (@0m/ft): 50/60Hz 0.1A • Max.
  • Página 5 NO SUCTION LIFT - SANS ASPIRATION - KEINE SAUGHÖHE - NO TIENE ALTURA DE ASPIRACIÓN - SENZA ASPIRAZIONE - ОТСУТСТВИЕ ПОДЪЕМА ВСАСЫВАНИЯ - BEZ WYSOKOŚCI SSANIA - NO ELEVADOR DE ASPIRAÇÃO 10m max. rec. head 115V 60Hz & 230V 50Hz 7m max. rec. head 230V 60Hz SILENT + MINI ORANGE LITRES PER HOUR - LITRES PAR HEURE - LITER PRO STUNDE - CAUDAL EN LITROS/HORA - LITRI PER ORA - ЛИТРОВ В ЧАС - MAX RECOMMENDED HEAD - HAUTEUR MAXIMALE LITRÓW NA GODZINĘ...
  • Página 6 1. ABOVE CEILING - AU-DESSUS D PLAFOND - IN DER ZWISCHENDECKE - SOBRE EL TECHO - SOPRA IL CONTRO-SOFFITTO - ВЫШЕ ПОТОЛКА - POWYŻEJ PUŁAPU - ACIMA DO TECTO 2. INSIDE CONDUIT - DANS LE CONDUIT - IM KANAL - DENTRO DE UN DUCTO - DENTRO LA CANALINA - ВНУТРИ...
  • Página 7 Install a 1 amp inline fuse. The high-level safety switch should be Installer un fusible de 1 AMP. Le commutateur de haute sécurité 1. SIPHONING, SIPHONNAGE, HEBEREFFEKT, SIFÓN, wired to prevent the continued operation of the air conditioning doit être connecté de façon à éviter l’opération continue de , SIFONE, СИФОНИРОВАНИЯ, SYFONOWANIA unit in the event of this Aspen pump failing.
  • Página 8 • This Aspen pump, like all mechanical • Cette pompe, comme tout autre équipement equipment, requires maintenance. mécanique, exige une maintenance. AL A RM / VO LT FR E E - AL AR M E/ S AN S C ON TA CT DE VO LTA G E - A LA R M / PO T EN T IA L FR E I - R E LÉ...
  • Página 9 Fault: Pump runs all the time. Fault: Pump stops and starts and makes a loud noise. Die Pumpe läuft ständig. Die Pumpe arbeitet normal, macht aber hin und wieder sehr starke Geräusche. 1. Is the float positioned with the magnet uppermost? 1. The water is siphoning through the pump. Fit an Anti 1. Ist der Schwimmer mit dem Magneten oben eingebaut? 2. Is the reservoir lid (sensor) located firmly onto the reservoir, with Siphoning Device following step 10 on page 12.
  • Página 10 Difetto: La pompa funziona di continuo. Difetto: La pompa attacca e stacca ed è molto rumorosa. Błąd: Pompa pracuje cały czas. Błąd: Pompa zatrzymuje się i zaczyna hałasować. 1. Il magnete del galleggiante è rivolto verso l’alto ? 1. L’acqua sta creando un sifone all’interno della pompa (installare 1. Czy pływak jest umieszczony magnesem do góry? 1. Woda syfonuje przez pompę. Należy zainstalować 2. Il coperchio è posizionato saldamente sul serbatoio, con il un dispositivo anti-prelievo seguendo il passaggio 10 a pag.
  • Página 11 LIME ORANGE AQUA aspen silent + pumps WW W. A SP E N P U M PS . C O M designed by engineers for engineers 40531-silent-plus orange-manual-0416.indd 20 04/05/2016 14:36...