Comunello Automation QUAD-230V-HP Instrucciones De Uso Y De Instalacion página 6

Idiomas disponibles
  • ES

Idiomas disponibles

In the eventualities of connections with devices connected in parallel on the same power supply line, the sizing of the cables shown in Table
1 must be re-evaluated on the basis of the absorptions and the actual distances.
3 TECHNICAL SPECIFICATIONS
Flashing light output no.1:
Flashing light output no.2:
Motors output:
Electric lock output:
Photocells power supply:
Pilot light output:
Working temperature:
Radio receiver:
Transmitters:
Max TX codes stored:
Board dimensions:
Fuse 1:
Fuse 2:
LED output
Services output
4 CONNECTION WITH ONE MOTOR
FORT
4.1
MOTOR OUTPUT 1
BROWN
Open
BLUE
GND
BLACK
Close
CN1
SW2 setting to have an opening to the LEFT (inner side view)
SW2
ON
1
2
INV
MOT 1
COMUNELLO ®Copyright 2021 - All rights reserved
34
230 V~ 500 W max.
24 V~ 4 W max.
230 V~ 2 x 500 W max.
12 Vcc 15 W max.
24 V 5 W max. AC
24 V~ 4 W max.
-20 ÷ 55 °C
433 Mhz
18 Bit o Rolling Code
120 (CODE PP o CODE PED/2°CH)
160 x 107 mm.
T 6,3 A 250V (Delayed fuse)
T 0,5 A 250V (Delayed fuse)
24Vcc Pilot light
24 V 5 W
MOTOR OUTPUT 2
DO NOT USE
ON
MOTOR
SW2 setting to have an opening to the Rights (inner side view)
ON
MOT 1
SW1
1
2
In this mode SW1 has been adjusted with:
1
M2 NOT
DIP1 OFF : only MOTOR 1 is considered
CONSID.
DIP2 ON : NOT USED
SW2
1
2
INV
loading