Comunello Automation QUAD-230V-HP Instrucciones De Uso Y De Instalacion página 15

Idiomas disponibles
  • ES

Idiomas disponibles

7 DETAILED DESCRIPTION OF ALL FUNCTIONS
ELECTRICAL CONNECTIONS
7.1
L:
230 V~ Line input (Phase)
N:
230 V~ Line input(Neutral)
LAMP 230~:
Flashing Light Output 1 (230 V~ Neutral)
LAMP 230~:
Flashing Light Output 1 (230 V~ Phase)
MOT1 OPEN:
Operator 1 opening output
MOT1 COM:
Operator 1 output common
MOT1 CLOSE:
Operator 1 closing output.
MOT2 OPEN2:
Operator 2 opening output
MOT2 COM2:
Operator 2 output common
MOT2 CLOSE2: Operator 2 closing output
CN2:
2nd CH:
Aux Radio CH Output (Free Contact max load 30V DC 1A)
2nd CH:
Aux Radio CH Output (Free Contact max load 30V DC 1A)
FOTO +
Photocell control and power supply
LAMP 24V
Signal light output 24Vac
GND
Common GND input
DS2
Safety device input 2 (NC)
DS1
Safety device input 1 (NC)
STOP 8K2
Block / 8K2 input
GND
Common GND input
P PED:
Ingresso Puls. Pedestrian/Single Door/open button input (NO)
PP:
Open-close/close command button input (NO)
ELS +
Electric lock output +24Vdc
ELS -
Electric lock output -
24V 5W
Services output (+24Vdc)
GND:
Common GND input
SPIA+24V LED:
Output indicator lamp (+24 V / 4 W)
ANT-:
Chassis ground input (sheath)
ANT+:
Antenna hot pin input
CN3:
ENC1 +:
Motor 1 Encoder power supply input
ENC1 E:
ENC1 Motor 1 Encoder signal input
GND:
Common GND input
MOT1 FCA:
Motor 1 Opening Limit Switch input (NC)
MOT1 FCC:
Motor 1 Closing Limit Switch input (NC)
ENC2 +:
Motor 2 Encoder power supply input
ENC2 E:
Motor 2 Encoder Signal input
ENC2 GND:
Common GND input
MOT2 FCA:
Motor 2 Opening Limit Switch input (NC)
MOT2 FCC:
Motor 2 Closing Limit Switch input (NC)
TRANSFORMATOR CONNECTIONS
CN5 (1st):
1:
230 V~ Transformer Primary Winding Input
2:
230 V~ Transformer Primary Winding Input
CN4 (2st):
1:
Transformer SEC 1 output 11.8V 3.5A
2:
Transformer SEC 1 output 11.8V 3.5A
3:
Transformer SEC 2 output 25V 0.8A
4:
Transformer SEC 2 output 25V 0.8A
FUNCTIONAL CHARACTERISTICS
7.2
7.2.1 - AUTOMATIC OPERATION (OPEN/CLOSE):
When either a stored remote or the connected low voltage pushbutton panel is used to control the gate, operation is as follows: the first
command opens the gate until motor time elapses or until the gate reaches its opening limit position; the second command closes the
gate; if another command is transmitted before motor time has elapsed or before one of the two limiters has been reached, the control unit
reverses the movement direction during both opening and closing.
7.2.2 - STEP-BY-STEP OPERATION:
When the LED L1 of the main menu is turned on, when either the remote or the low voltage control pushbuttons are used to control the