K2 Pumps WPS05004K El Manual Del Propietario página 7

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3. PUMP TO PRESSURE TANK AND TO HOUSE CONNECTION
NOTE: The pump must be within 4' of the tank to prevent switch chatter. Check the tank recharge on a
yearly basis.
Pre-Charge Tank Connection
1.
Most pressure tanks will have a 1in. inlet elbow on
the bottom. Connect to this elbow with a 1in. PVC
MPT×S Male Adapter and a short piece of 1in.PVC
rigid Pipe. (Fig. 1)
3.
Cement a 1in.PVC rigid Pipe into elbow then
cements a 1in.×3/4in.PVC Reducing Male Adapter.
(Fig. 3)
5.
Make the connection to the house plumbing. From
the tee, install pipe and 3/4in.Slip×Slip Ball Valve
(optional). (Fig. 5)
For Professional Technical Support call 1-844-242-2475
2.
Cement a 1in.PVC 90-Degress S×S Elbow. (Fig. 2)
4.
Cement a 3/4in.PVC rigid Pipe into a 3/4in. CPVC
CTC Socket Tee Fitting. Cement 3/4in. PVC MPT×S
Male Adapter into 3/4in.PVC rigid Pipe that connect
with a 3/4in. PVC FPT×FPT Union. (Fig. 4)
6.
Install a 1 in. male NPT x 1 in. female NPT x 1 in.
female NPT galvanized tee to the outlet of the
pump. (Fig. 6)
7
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Wps07504k

Tabla de contenido