Modello - Modèle - Model
Modell - Modelo
Fabbricante - Constructeur
Manufacturer - Hersteller
Fabricante
27. TEMPERATURE SETTING AND CONTROLS (Electronic)
Each refrigerating appliance is provided with an electronic thermostat (1) for automatic maintenance of the temperature inside the tank.
This temperature adjuster is gauged by the factory and should not be touched by the user.
Only if the average internal temperature is too cold or not cold you can proceed as follows:
1.
Press the (SET) key in order to see on display the temperature set point.
2.
Press the (SET) key in order to modify the temperature set point.
3.
It will exit from setting state if without operations within 5 seconds.
28. MALFUNCTION AND REMEDIES
Most of the functioning inconveniences are generally due to defective electrical connections.
These problems can usually be solved on the place.
POSSIBLE CAUSE
Check that the unit is properly plugged
Check that the unit is properly plugged
Check that the plug cord is broken
If power failure is not due to any of the above causes, call the nearest after-sales service immediately, empty the cabinet and store the foods
in coldrooms or refrigerators that may ensure their preservation temperature.
THE INTERNAL TEMPERATURE IS NOT COLD ENOUGH
POSSIBLE CAUSE
Check the perfect closing of the glass covers
Make sure that the cabinet has been filled correctly
Check that the unit is not adjacent to sources of heat
Check that behind the cabinet air can properly circulate
Check the temperature setting
Check that there is not too much ice on the tank walls
If failure to cool should is not due to any of the above reasons it it persists on even after the above checks, resort to the nearest after-sales service.
POSSIBLE CAUSE
Check that all the bolts and nuts are properly fastened
Check that the unit is placed on an even surface
Check if any pipe or fan is in contact with any other part of the body
Should the inconvenience persist, contact the nearest after-sales service.
GELÉ
EPTA S.p.A. - Sede legale
Via Mecenate, 86 - 20138 Milano – Italy
Capitale € 68.515.000 - R.E.A./MI – 1730229
Registro delle Imprese e Cod.Fiscale n. 04160730968
Partita IVA 04160730968
THE UNIT DOES NOT START
THE UNIT IS NOISY
SOLUTION
Insert the plug
Insert the plug correctly
Replace the plug cable
SOLUTION
Close correctly
Load the product correctly
Position the equipment correctly
Position the equipment correctly
Set the correct temperature
Defrost the equipment
SOLUTION
Screw in the screws
Position the equipment correctly
Switch off the counter and distance the
parts in contact in the event the problem
persists, contact the support service.
1 9 / 5 0
PAGE
N° DOC
AUTHORISED STAFF
User
User
Technical support
AUTHORISED STAFF
User
User
User
User
Technical support
User
AUTHORISED STAFF
User
User
Technical support