INSTALL DISCHARG COLLAR
Install the discharge collar into the duct
connector of the range hood.
CONNECT DUCTWORK
Adjust the width of the flue mounting bracket
to equal the inside width of decorative flue.
Insert and tighten mounting screws to hold
bracket width.
Use mounting screws (4.8x38mm) and wall
anchors to secure flue mounting bracket to
the ceiling as shown.
FLUE MOUNTING
BRACKET
1. Use 6" round metal duct to connect the
duct collar on the hood to the ductwork
above.
2. Use duct tape to make all joints secure
and air tight.
3. Carefully place the lower decorative flue
into the recessed area of the range hood
top.
4. Extend the upper flue to the ceiling and
secure with two mounting screws
(3.9x9.5mm).
All manuals and user guides at all-guides.com
MOUNTING SCREWS
FASTEN FLUE TO
UPPER BRACKET
WITH MOUNTING
SCREWS
(3.9x9.5mm)
- 7 -
DISCHARGE
COLLAR
=
MOUNTING
=
SCREWS
(4.8x38mm)
DECORATIVE
FLUE
DUCT TAPE
6" ROUND