5.7 Prevention of siphoning
If the toilet is below or less than 50 cm above the waterline there
is a danger of water siphoning back into the toilet (supply pipe).
An air vent must be fitted at the highest point in the supply pipe
in order to prevent siphoning (see the installation examples).
5.8 Testing
Open the ball valve in the water supply pipe completely so that
there will be a sufficient supply of water for flushing. Press the
button once and check whether the cycle is carried out prop-
erly. Throw a few pieces of toilet paper into the pot and check
the cycle again.
Check that there are no leaks at any of the connections.
6 Use
• Make sure that the ball valve in the water supply pipe is
open.
• A short or long flush can be used.
• Short flush (1.2 litres): Press the 'ECO' button.
• Long flush (2.2 litres): Press the 'NORMAL' but-
ton.
• After using the toilet shut off the ball valve.
If the toilet has not been used for some time it is advisable to
rinse it with clean water a few times before using it.
The following precautions must be taken during periods of frost
(winter) :
• Shut off the water supply to the toilet.
• Pump the toilet empty by pressing the button
with the pump symbol and holding this in.
• Pour about 2 litres anti‑freeze into the toilet pot.
• Drain the pipes.
Anti-freeze is poisonous and must never be drained into the
external water.
8
110129.01
7 Maintenance
Traditional toilet cleaners can be used to clean the toilet and to
remove scale.
In order to prevent scale deposits from building up in the pump
these must be removed regularly as follows:
• Shut off the water supply by closing the ball valve.
• Pump the toilet empty by pressing the button
with the pump symbol and holding this in.
• Pour about 1 litre of vinegar or scale remover into the toilet
pot and let it soak for some hours.
• Open the ball valve again and carry out several cycles in
order to flush the toilet pot thoroughly and remove all the
water used from the pump.
How often the scale needs to be removed depends on the hard-
ness of the water, but it should be done at least twice a year.
Do not use products based on sodium (unblocking products)
or solvents.
If seawater is used for flushing the toilet should be rinsed
through with fresh water every so often to prevent salt deposits
from building up.

8 Technical details

Voltage
Current
Maximum vertical lift
in outlet
Maximum hose length
Pump capacity at discharge
height of 3 metres
Maximum water
temperature
Noise level
Protection
Weight
:
12 V
24 V
:
25 A
15 A
:
3 metres
:
30 metres
:
3 6 litres/min @ 12 V
4 3 litres/min @ 24 V
:
35˚C
:
61 dBA
:
IPX4
:
17.5 kg