7) Check that the voltage given on the appliance label corresponds to the mains voltage.
8) Before connecting the appliance to the mains, check that the cable and the appliance are not damaged in any way.
9) The appliance power supply cable must form an appropriate loop, facing downwards (DRIP LOOP - Fig. 4), to prevent any runoff
water from coming into contact with the socket itself.
10) Do not place the supply cable underground, but follow the installation instructions prescribed by the local regulations in
force, and consult a qualified installer and electrician.
11) When installing the appliance, do not use the supply cable to lift it.
12) Before starting up the appliance, check that it has been correctly installed.
13) Do not make any technical alterations to the appliance. Use only original spare parts and accessories.
14) WARNING: avoid exposure to direct sunlight. Do not use or keep the appliance in an area subject to freezing. In winter, it is
EN
necessary to remove, empty and position the appliance so that it is protected.
15) The appliance must not be operated dry. Do not use this appliance for filtering caustic, abrasive, inflammable, aggressive or
explosive liquids, and even drinking water.
16) WARNING: never look directly at the UV-C lamp when it is switched on.
17) WARNING: these appliances contain glass. Handle with due care.
18) WARNING: never connect the filters to the public water supply network.
19) WARNING: these UV-C filters must not operate immersed in water. If they should accidentally fall into it, before recovering them,
disconnect the plugs from the power supply socket. Take the same care if you should notice that any parts of the appliance are wet.
20) When used outdoors, install and properly fix the filter near the pond edge, make sure that it is installed in such a manner that
it cannot get into the water accidentally, and that the area, where it is installed, is not subject to flooding. Minimum safe distance
from water should be 2 m, according to international standard IEC 60364-7-702.
II.
NAME OF COMPONENTS (Fig. 1)
1.
Filter body
2.
Quartz tube
3.
UV-C lamp
4.
O-ring for quartz tube
5.
Aluminium retaining ring
6.
Clamp ring
7.
Safety screw
8.
Unlock button
9.
Filter head
10.
Filter head O-ring
11.
Power cord
12.
Hand fitting nozzle
13.
Closure cap
III.

INSTALLATION

The PURE LIGHT UV-C filter can be used as an independent filtering system for transmission and filtering of water coming from
the pump, and in a combination with other pressure and pressureless filters of mechanical or biological type, such as PREXO,
PURO and PRATICO from NEWA Pond line of filters (Fig. 4-5). In this case, refer to instructions for use of the above-mentioned
appliances for assembling and installation of PURE LIGHT UV-C filter.
WARNING:
• The filter must not be immersed into water (Fig. 6)
• The filter cannot function under dry conditions, but it must be connected to a pump. To determine which is the most suitable
pump for your intended purpose, follow the application table (Fig. 3).
• To ensure proper functioning, install the device ONLY IN THE ALLOWED POSITIONS (Fig. 7).
Prior to installation of PURE LIGHT UV-C filter, it is recommended to:
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE!