tizing solution (100 PPM available chlorine concentration or 1
spoon of sodium hypoclorite diluted with two litres of water)
according to your local Health Codes and manufacturer's speci-
fications.
2 Pour the solution into the bowl(s).
3 Using a brush suitable for the purpose, wipe the solution on
all surfaces protruding above the solution-level and on the
underside of the top cover(s).
4 Install the top cover(s) and operate the unit. Allow the solu-
tion to agitate for about two minutes. Drain the solution out of
the bowl(s).
5 Use fresh product to chase any remaining sanitizer from the
bowl(s). Drain this solution. Do not rinse out the machine.

6 ROUTINE MAINTENANCE

Daily: inspect the machine for signs of product leaks past seals
and gaskets. If proper assembly does not stop leaks around
seals or gaskets, check for improper lubrication, worn or
damaged parts. Replace parts as needed with original spare
parts from the supplier.
6. 1 MAINTENANCE (TO BE CARRIED OUT BY
QUALIFIED SERVICE PERSONNEL ONLY)
Monthly
: clean all internal components, primarily the conden-
ser, using compressed air.
To clean these internal parts, unplug the unit or switch off the 2-
pole wall breaker, then remove front panel (dispensing side).
Condenser fins are very sharp. Use extreme caution when cle-
aning.