KENMORE ELITE 253.76062 Manual De Uso Y Cuidado página 8

Idiomas disponibles

Idiomas disponibles

ADDiTiONAL THINGS YOU SHOULD KNOW
Now that you understand
the basic operation
functions, here are mare control features
with which you should became
familiar.
The "cool" circuit has an automatic
3 minute time delayed
start if the unit is turned off and on quickly. This prevents
overheating
of the compressor
and possible circuit breaker
tripping.
The fan will continue to run during this time.
There is a 2-Second
delay for the compressor shutting down when selecting
FAN ONLY. This is to cover the possibility
of having to roll through to select another mode.
The control will maintain the set temperature
within 2 degrees Fahrenheit,
between
60F and 90F degrees.
If the unit is turned off in heat mode (if applicable)
or fan only mode, it will return to the same setting when it is turned
on again.
When the unit is turned off in cool or energy
saver mode, it will run in energy
saver mode when it is turned
on again,
but
the setting of temperature
and fan speed will remain.
Models
with a key hole overflow drain hole can use drain kit 5304481680
to connect a 1/2 inch drain hose for safe
disposal
of excess system water. This part can be ordered
at www.SearsPartsDirect.com.
The control is capable
of displaying
temperature
in degrees
Fahrenheit
or degrees
Celsius. To convert
from one to the
other and back, press and hold both the "TEMP/TIMER"
Up(A)
and Down (v)
buttons for 3 seconds.
FAULTCODES :
if the display reads "ES" or "AS", a sensor has failed. Contact 1-800-4-MY-HOME®
for repair.
AUTO RE-START:
Q
Evaporator
coil sensor
U
Air temperature
sensor
After a power outage, the unit will remember the last setting and return the unit to the same setting once power is restored.
LOUVERS
AUGER WHEELS
Air Directional
Louvers
Air directional
louvers control air flow direction.
Your air conditioner
has
the 8-way
directional
system described
below.
The louvers will allow you to direct the air flow Up or Down and Left or
Right throughout
the room as needed.
Rotate the Auger Wheels until the
desired
Left or Right direction
is obtained.
Pivot horizontal
louvers with
your fingertips
until the desired
Up/Down
direction
is obtained.
There are
a total of 8 possible air directional
orientations
available
with this system.
8