MOTOR PROTECTOR
This vacuum
has a motor protector
by-
pass valve which automatically
opens to
provide
cooling
air to the motor when a
clog prevents
the normal
flow of air to the
motor. If the by-pass
valve opens
to
prevent
motor overheating
and possible
damage
to the vacuum,
you win notice a
change
of sound as air rushes through
the
valve opening.
Note: Do not
block motor
protector.
Motor
Protector
To correct problem: See the TROUBLE-
SHOOTING section (page 22).
Note: The motor protector
may open when
using attachments
or when cleaning
new
carpet,
due to reduced
airflow caused by
the attachments
themselves
or by new
carpet fuzz filling the dust bin quickly.
PERFORMANCE
INDICATOR
When the unit is
running with
__
_
normal
air flow,
the light on the
performance
indicator
is off.
_
-_-i&\_
The light comes
on whenever
the _
p
airflow becomes
erformanclndicator
e
blocked.
If that
occurs, check the dust bin, clean or
replace clogged
filters, and check other
possible
clog locations
shown in CLOG
REMOVAL
(see page 19).
To correct problem:
See the TROUBLE-
SHOOTING
section
(page 22).
Note: The light may also come on when
using attachments,
due to reduced
airflow
through
the attachment.
Note: In some cases, the performance
indicator
light may not come on if the
motor protector
has opened.
AGITATOR
THERMAL
PROTECTOR
This agitator has a thermal protector which
automatically
trips to protect the agitator
motor from overheating.
If a clog prevents
the normal flow of air to the motor, the
thermal protector
turns the motor off
automatically
to allow the motor to cool in
order to prevent possible damage to the
vacuum.
During this time the headlight and
suction motor will remain on.
/
To correct problem:
If this occurs, turn the
vacuum off and unplug the power cord
/
from the outlet to allow the agitator to cool
and the thermal protector to reset.
Check
for and remove clogs, If necessary.
Also
check and replace any clogged filters. Wait
approximately
thirty (30) minutes and plug
the vacuum in and turn back on to see if the
motor protector
has reset. "l_e motor
protector will not reset if the vacuum is not
turned off even if the vacuum has cooled down.
AGITATOR
OVERLOAD
PROTECTOR
The agitator has built-in protection
against
motor damage
under severe jam conditions.
If the agitator slows down or stops, the
agitator overload protector
shuts off the
agitator. The suction motor will continue to run.
To correct problem: Turn off and unplug
vacuum, remove obstruction,
then press
reset button.
.IJ_
To reset: Push in
the agitator
"7"-_-
._-_/'f
"N
overload
protector _'/,,..._
_
/_
button.
_/(_,,,_tI_,_
"_"
Agitator
Reset
MOTOR THERMAL
PROTECTOR
This vacuum has a thermal protector which
automatically
trips to protect the vacuum
from overheating.
The thermal protector
turns the motor off automatically
to allow the
motor to cool in order to prevent possible
damage to the vacuum.
13
To reset:Turn off and unplug the vacuum
from the outlet to allow the vacuum to cool.
Check for and remove any clogs. Also
check and replace any clogged filters. Wait
approximately 50 minutes and plugthe
vacuum in and turn back on to see ifthe
thermal protector has reset. In some cases,
the unitmay suddenly restart. DO NOT