USAGE AND MAINTENANCE INSTRUCTIONS
You have purchased a DENIA product. Apart from correct maintenance, our
woodstoves require installation strictly in accordance with legislation. Our products
conform to the EN 13240:2001 and A2:2004 European norm, however it is very
important for you the consumer to know how to correctly use your woodstove following
the recommendations we set out. For this reason, before installing our product you must
read this manual carefully and follow the usage and maintenance instructions.
POSITION OF THE SMOKE PIPE
1) Place the first tube in the smoke outlet circle at the top of the stove, and attach the
"other" tube onto the end.
2) Join it to the rest of the chimney.
3) If the tubing reaches the exterior of your home, place the "hat" onto the end.
INSTALLATION
You have purchased a wood burning stove with a vermiculite insulated combustion chamber.
Do not remove the vermiculite boards!!!!!
- All local regulations, including those referring to National and European standards
need to be complied with when installing the appliance.
- The installation of the smoke outlet must be as vertical as possible, avoiding the use
of joints, angles and deviations. If the installation is connected to a masonry chimney
pipe we recommend the tubes reach the exterior exit. If the smoke outlet is via tubing
only, at least three meters of vertical tubing are recommended.
- IMPORTANT: The installation and regular cleaning of this stove must be carried out by
a qualified professional. The ventilation opening must never be obstructed.
- IMPORTANT: The woodstove must be installed in a well ventilated place. It is advisable
to have at least one window in the same room as the stove which can be opened.
- The tube connections should be sealed with a refractory putty to prevent soot from
falling through the joints.
- Do not position the stove near combustible walls. The stove should be installed on a
non-combustible floor surface, if not a metal plate covering the bottom surface area
of the stove must be placed underneath it and extend further than 15 cm at the sides
and 30 cm at the front.
- Whilst the stove is in use remove any material nearby which could be damaged by
the heat: furniture, curtains, paper, clothes, etc. The minimum safety distance from
adjacent combustible materials is as shown on the last page of this manual.
- The ease of access for the cleaning of the product, smoke outlet and chimney must be
considered. If you intend to install your stove near an inflammable wall, we advise you
to leave a minimum distance to facilitate cleaning.
- This stove is not suitable for installation in any chimney system shared by other sources.
- The stove should be installed on flooring with adequate support. If your current floor
4