NOTA BENE : For the deflector, the
E notches are located at the fore
part of the appliance (Fig 25) when
this last one is set up.
For reinstall the deflector, carry out the same
-
operations in the reverse order.
Thoroughly inspect the condition of the
-
fireplace and all seals, in particular : seals,
locking mechanisms, bearing surfaces (door,
frame).
After removing the tube cover :
-
Thoroughly inspect the condition of the
.
chimney flue and the connecting tube: all
connections must be mechanically sound
and retain their tightness.
Use a vacuum cleaner to clean the
.
convection circuit around the fireplace,
inside the hood and in the hot air outlets.
•
Clean the appliance using a brush and a vacuum
cleaner.
If an anomaly is detected, have the unit or the
installation repaired by a certified professional.
After a long off-period :
Check that nothing obstructs any pipes before using
the stove again.
6.2 - Routine maintenance
•
Clean the glass with a damp cloth and remove
the ash. If necessary, use a special cleaning
product in accordance with the manufacturer's
instructions. Wait until the installation has
completely cooled down before performing this
operation.
•
Clean regularly the ventilation guides :
Using the tip of a metallic object (2), scratch
-
the inner edges of the cast iron to remove the
soot which may have formed.
Using a vacuum cleaner (1), remove the
-
particles and dust trapped between the door
and window (Fig. 26 and 27).
NOTE : The particles disrupt the formation of the
secondary air layer which protects the glass
from direct contact with the smoke and
assists in the complete combustion of the
wood.
These operations should be performed
whenever the glass is dirty and only once
the fireplace has completely cooled down.
•
Regularly clean the hot air outlets on the tube
cover. The outlets become quickly obstructed
with intensive operation. Select an adequate
cleaning interval.
www.pieces-de-poele.com
•
If servicing of the blower is necessary for any
reason whatsoever (Fig. 28) :
Disconnect the appliance (or switch off the
.
power).
Remove the 3 mounting screws (1) from
.
the fan support and the protective grille.
Remove the 2 screws and the 2 fan
.
washers (2).
Remove the grille by lifting it.
.
Pull the fan at a slant angle.
.
NOTE : For terminal strip connections, refer to Fig. 29
and Fig. 30.
19