Installation; Installing/Replacing The Lamps; Connection With The Mains - EuroLite FL-1100 Flame-Light Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTALLATION

Installing/Replacing the lamps

Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need six 230V/35W GU10 lamps.
During the operation, the lamp reaches temperatures of up to 145° C.
Procedure:
Step 1: If replacing the lamp, remove the old lamp from the lamp-socket.
Step 2: Insert the new 230V/35W GU10 lamp into the lamp-socket.
Installation
Install the device out of the public area.
Only install the machine on scratch resistant surfaces.
This device is constructed for a standing installation only.

Connection with the mains

Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
DANGER TO LIFE!
Only install the lamps with the device switched off!
Unplug from mains before!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
International
L
N
CAUTION!
13/27
00021847.DOC, Version 1.2
Tabla de contenido