OBSERvED PROBLEM
ODS/pilot lights but flame
goes out when control knob
is released
Burner does not light after
ODS/pilot is lit
Delayed ignition of burner
Burner backfiring during
combustion
Burner plaque(s) does not
glow (Infrared models only)
Yellow flame during burner
combustion
110720-01M
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Control knob not fully
pressed in
2. Control knob not pressed in
long enough
3. Equipment shutoff valve not
fully open
4. Thermocouple connection
loose at control valve
5. Pilot flame not touching
thermocouple, which allows
thermocouple to cool, caus-
ing pilot flame to go out. This
problem could be caused by
one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
6. Thermocouple damaged
7. Control valve damaged
1. Burner orifice is clogged
2. Inlet gas pressure is too
low
1. Manifold pressure is too
low
2. Burner orifice is clogged
1. Burner orifice is clogged or
damaged
2. Burner damaged
3. Gas regulator defective
1. Control knob set between
locked positions
2. Inlet gas pressure is too
low
3. Plaque damaged
1. Not enough air
2. Inlet gas pressure is too
low
3. Gas regulator defective
www.desatech.com
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep
control knob pressed in 30
seconds
3. Fully open equipment shut-
off valve
4. Hand tighten until snug,
then tighten 1/4 turn more
5. A) Contact local natural or
propane/LP gas company
B) Clean ODS/pilot (see
Cleaning, page 17) or re-
place ODS/pilot assembly
6. Replace pilot assembly
7. Replace control valve
1. Clean burner orifice (see
Cleaning, page 17) or re-
place burner orifice
2. Contact local natural or
propane/LP gas company
1. Contact local natural or
propane/LP gas company
2. Clean burner orifice (see
Cleaning, page 17) or re-
place burner orifice
1. Clean burner orifice (see
Cleaning, page 17) or re-
place burner orifice
2. Replace burner
3. Replace gas regulator
1. Turn control knob until it
locks at desired setting
2. Contact local natural or
propane/LP gas company
3. Replace burner
1. Check burner for dirt and
debris. If found, clean burn-
er (see Cleaning, page 17)
2. Contact local natural or
propane/LP gas company
3. Replace gas regulator