Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
DEVICE SETTINGS (Settings)
Starting from the main display, press on the right push button rotary encoder to move to the main menu. Rotate the left encoder (SELECT) to select
"Settings" menu item (as indicated by selector arrow on left) and confirm by pressing the left encoder (ENTER). This will take you to the submenu
for setting the submenu options (see table, select via SELECT, confirm via ENTER, change value or status via SELECT, confirm via ENTER).
Settings (bold = factory setting)
Display Flip
=
Flips the display
Display Time off
=
Display backlight
DMX Fail
=
operating mode if DMX
signal is lost
Dimmer Curve
=
Dimmer Curve
Dimmer Response
=
Dimmer behavior
Red Shift
=
Imitates color drift by
dimming one of the
halogen spotlights. The
dimming of the spotlight
automatically changes
the color temperature
along a rising curve of
warm white and amber
(and vice-versa).
PWM Frequency
=
LED PWM frequency
Color Calibration
=
Calibration of the color
Standing Position
No rotation of display
Hanging Position
Display rotates by 180°
(such as when installed overhead)
Display always on
permanently on
Display off after 20s
deactivates after approx. 20 seconds of inactivity
Hold
last command is held
Blackout
activates Blackout
User Color 8
activates User Color 8
Linear
The light intensity climbs linearly with the DMX value
Exponential
The light intensity can be set finely in the
lower DMX value range and roughly in the
upper DMX value range
Logarithmic
The light intensity can be set roughly in the
lower DMX value range and finely in the
upper DMX value range
S-curve
The light intensity can be set finely in the lower and
upper DMX value ranges and roughly in the medium
DMX value range
LED
The spotlight reacts abruptly to changes in the DMX
value.
Halogen
The spotlight behaves similar to a
halogen spotlight with soft changes in brightness.
No
Color drift deactivated
Dim To Warm
Color drift activated
600 Hz / 1200 Hz /
Sets the LED PWM frequency
2000 Hz / 4000 Hz /
6000 Hz / 25k Hz
RAW
R, G, B and W with maximum value of 255
User Calibration
Press center encoder = Switch between R+G and
(Custom adjustment of
B+W (Color)
R, G, B, and W by values
Rotate center encoder = Configure value of R or B
ranging from 000 to
Press right encoder = Move up one level in the menu
255, independent of
navigation (ESC)
mode)
Rotate right encoder = Configure value of G or W
Press left encoder = Confirm and save settings

Factory Calibration

Factory preset calibration of R, G, B and W
(independent of mode). Select this setting for correct
depiction of color tones and presets in the stand-alone
modes CCT and Gel, as well as to activate CCT and the
Gel presets via DMX.
13