Battery Cable Connection (Electric Start Only); Add Engine Oil - Powermate CX6500E Manual Del Propietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

.
9
2
13
Battery Cable Connection
(electric start only)
Do not make battery connections
in reverse. Doing so will result in
equipment damage.
The unit has been shipped with the battery
cables disconnected.
You will need two 8mm box wrenches to con-
nect the battery cables. See
1. Cut off cable ties securing battery cables
and remove red cover from battery termi-
nal.
2. First, connect the red cable to the positive
(+) battery terminal with the bolt and nut
supplied.
3. Make sure connections are secure and
slide rubber boot over the positive (+) bat-
tery terminal and connection hardware.
4. Connect the black cable to the negative (-)
battery terminal with the bolt and nut sup-
plied. Slide rubber boot over the negative
(-) battery terminal and connection hard-
ware.
5. Make sure all connections are secure.
8
11
Figure 2-7. Wheel, Handle and Foot Assembly
CAUTION
(000167)
Figure
4-5.
11
4
5
8
10
NOTE: If the battery is unable to start the
engine, charge it with an appropriate 12V
charger or manually start the generator and let
run until charged.

Add Engine Oil

Engine damage. Verify proper type and quantity of
engine oil prior to starting engine. Failure to do so
could result in engine damage.
1. Place generator on a level surface.
2. Verify oil fill area is clean.
3. Remove oil fill cap and wipe dipstick clean.
See
Figure
Owner's Manual for Portable Generator
12
7
6
1
CAUTION
2-8.
3
001597
(000135)
Tabla de contenido
loading

Este manual también es adecuado para:

Cx8000e

Tabla de contenido