4. CONTROLS

All units are equipped with an integrated control located under the unit, on the recessed side of electrical compartment. Plug the unit.
4.1 U
B
S
NITS
OOTING
EQUENCE
The unit booting sequence is similar to a personnal computer boot sequence. Each time the unit is plugged after being unplugged, or after
a power failure, the unit will perform a 30-second booting sequence before starting to operate.
During the booting sequence, the integrated control LED will light AMBER for 10 seconds. After that, the LED will light RED for the rest of
the booting sequence. During this RED light phase, the unit is checking and resetting the motorized damper position. Once the motorized
damper position completely set, the RED light turns off and the booting sequence is done.
NOTE: No command will be taken until the unit is fully booted.
4.2 I
C
NTEGRATED
ONTROL
Use the push button (1) to control the unit. The LED (2) will then show on which mode the
unit is in.
Refer to table below to see how to operate the unit using its integrated control.
P
RESS ON PUSH BUTTON
O
NCE
T
WICE
T
HREE TIMES
If a problem occurs during the unit operation, its integrated control LED (2) will blink. The color of the blinking light depends on the type
of error detected. Refer to Section 9 Troubleshooting on page 19 for further details.
NOTE: When using main control, the integrated control must be turned off.
LED
COLOR
A
U
MBER
NIT IS ON
G
U
REEN
NIT IS ON
N
O LIGHT
R
ESULTS
L
OW SPEED
H
IGH SPEED
U
OFF
NIT IS
12
2
1
B
OTTOM OF THE UNIT
VD0206

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Hrv150te

Tabla de contenido