Dear Customer,
We thank you for having chosen one of our products, the fruit of
extensive and continuous research for a superior product in terms of
safety, reliability and performance.
In this manual you will find all the information and advice you need to
use your product as safely and efficiently as possible.
ESSENTIAL INSTRUCTIONS
• This instruction booklet has been prepared by the manufacturer and
is an integral part of the product.
Its instructions are intended for the buyer and all individuals involved
in the installation, use and maintenance of the product.
• Read the instructions and the technical information contained in
this manual carefully, before proceeding with installation, use or any
repairs.
• Compliance with the instructions in this booklet guarantees the safety
of persons and of property; it also ensures more efficient operation
and an increased lifespan.
• The manufacturer declines all responsibility for damage caused by
failure to observe the installation, use and maintenance instructions
in this manual, for unauthorized product modifications or for use of
unoriginal aftermarket parts.
• Careful planning and risk analysis made by the manufacturer have
allowed for a safe product; however, before performing any operation,
it is recommended to carefully follow the instructions in this document
and keep it available at all times.
• The installation and use of the product must be made in accordance
with the manufacturer's instructions and in compliance with European,
national and local regulations.
• The installation, electrical connection, operational check, maintenance
and repairs are operations that must be performed by qualified and
licensed technicians that have appropriate knowledge of the product.
• The images shown in this manual are for explanatory purposes and at
times may not accurately depict the product.
For the restrictions, limitations and exclusions please refer to the
warranty included with the product.
In line with its policy of constant product improvement and renewal, the
manufacturer may make changes without notice.
This document is the property of the manufacturer; no part of it
may be disclosed to third parties without the written permission
thereof. All rights reserved by the manufacturer.
EXAMPLES OF FLEXIBLE PIPE CONNECTION
The hot air ducting set draws airflow from the top part of the stove and
channels it to other rooms with 0.75 mm flexible pipes.
Below are some examples on how hot air is channelled into adjacent
rooms.
Top stove performance is obtained by using Ø 75 flexible
a
pipes. Maximum ducting length depends on the configuration
installed (see later in manual).
a
Every bend and/or Y connector is comparable to 1 metre of
straight ducting.
The outlets must not be closed in order to avoid overheating.
a
The outlet must always be kept open and free of clogs in
cases where there is only one rear outlet from the fan.
a
The hot air ducting set cannot be installed on the top part of
the stove if the mid-top smoke flue is already installed.
The hot air ducting set cannot be installed on the top part of
a
the stove if the humidifier is already installed (optional).
The flexible pipe must always be insulated to avoid heat
a
dispersion and provide sound cladding for the air flow.
SOLUTION 1.
The appliance is installed with the ducting set output at the rear of the
stove (Fig. 1). In this case, the appliance heats the environment where it
is installed as well as the adjacent room via the rear ducting.
Fig. 1
A + n bends = 4 m max
SOLUTION 2.
The appliance is installed with the ducting set output at the rear of the
stove. Installation of a Y connector makes it possible to heat two other
adjacent rooms aside from the room of installation (Fig. 2).
Fig. 2
A+B + n bends = 4 m max
Outlet aperture must be partialised at short distance from the
a
Y coupling without ever closing it in order to avoid overheating
and achieve optimal ducting yield.
H07031720 / DT2002253 – 01