HEATER / FAN
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE INSTALLING
OR USING THIS HEATER.
To reduce the risk of fire, electric shock, or injury to persons, observe
the following:
1. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or tele-
phone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning de-
vice, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
5. This heater is hot when in use. To avoid burns, do not let bare skin
touch hot surfaces. Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes, etc. and curtains at least 3 feet
(0.9 m) from the front of the heater.
6. Extreme caution is necessary when any heater is used by or near
children or invalids and whenever the heater is left operating and
unattended.
7. Do not operate any heater after it malfunctions. Disconnect power at
service panel and have heater inspected by a reputable electrician
before reusing.
8. Do not use outdoors.
9. To disconnect heater, turn controls to off, and turn off power to heat-
er circuit at main disconnect panel (or operate internal disconnect
switch, if provided).
10. Do not insert or allow foreign objects to enter any ventilation or ex-
haust opening, as this may cause an electric shock or fire, or dam-
age the heater.
11. To prevent a possible fire, do not block air intakes or exhaust in any
manner.
12. A heater has hot and arcing or sparking parts inside. Do not use it
in areas where gasoline, paint, or flammable vapors or liquids are
used or stored.
13. Use this heater only as described in this manual. Any other use not
recommended by the manufacturer may cause fire, electric shock,
or injury to persons.
14. This product must be grounded.
15. Do not install heater in a tub or shower enclosure.
16. This product is designed for ceiling installation only. This product
is designed for installation in ceilings up to a12/12 pitch. Ductwork
must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.
17. Install heater at least 12 inches from floor or any adjacent wall.
18. Do not connect heater to dimmer switch or speed control.
19. Provide a separate 15 AMP circuit. Use 14 GA. power cable of type
which meets code. Use supply wiring rated for at least 90
20. For greatest efficiency, install heater so heat is directed toward tub
or shower area. Avoid directing toward walls or windows.
SAVE THESE INSTRUCTIONS
To register this product, visit:
www.nutone.com
PREPARATION
1. Remove the
grille bracket.
2. Remove the heater
assembly retaining
screw.
4. Remove fan assembly
retaining screws. Lift
fan assembly out of the
housing.
5. Slide the 4 hanger
bars into the slots
on each end of the
C.
O
housing - 2 hanger
bars per side.
MODEL 605RP
Page 1
3. Rotate heater assembly
and lift it up and out of the
housing.
Tabla de contenido
loading

Resumen de contenidos para NuTone 605RP

  • Página 1 MODEL 605RP Page 1 HEATER / FAN To register this product, visit: www.nutone.com READ AND SAVE THESE INSTRUCTIONS PREPARATION IMPORTANT INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE INSTALLING 1. Remove the OR USING THIS HEATER. grille bracket. To reduce the risk of fire, electric shock, or injury to persons, observe the following: 1.
  • Página 2 MODEL 605RP Page 2 INSTALLATION WARNING: To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicin- 2. Remove unit tem- ity of the heater. porarily, and pound nails partially into...
  • Página 3 MODEL 605RP Page 3 4. Use a flat-bladed screwdriver to remove the proper electrical knockouts. WIRE OPENING RELEASE SLOT If the switch has not been wired properly and wires need to be moved: 1. Each wire opening has a release slot.
  • Página 4 MODEL 605RP Page 4 OPERATION Before using heater, make sure heater has been properly installed according to installation steps beginning with the "PREPARATION" section on page 1.
  • Página 5 MODEL 605RP Page 5 MAINTENANCE The following maintenance and cleaning tasks can be performed by the user. All other servicing must be performed by an autho- rized technician If you have any questions, please consult with our customer service department at: 800-558-1711.
  • Página 6: Service Parts

    IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Página 7: Instrucciones Importantes

    MODELO 605RP Página 7 CALENTADOR / VENTILADOR Para colocar este producto, visite: www.nutone.com LEA Y CONSERVE ESTAS INSTRUCCIONES PREPARACIÓN INSTRUCCIONES IMPORTANTES LEA TODAS LAS INSTRUCCIONES ANTES DE INSTALAR O USAR ESTE CALENTADOR. 1. Quite el soporte Para reducir el riesgo de incendios, descargas eléctricas o lesiones personales, de la rejilla.
  • Página 8: Instalación

    MODELO 605RP Página 8 INSTALACIÓN ADVERTENCIA: Para reducir el riesgo de incendio, no almacene ni use gasolina u otros vapores y líquidos flamables en las 2. Quite temporalmente cercanías del calentador. la unidad y clave parcialmente los PRECAUCIÓN: Temperatura alta, el riesgo de incendio, mantenga clavos en las vigas los cables eléctricos, cortinas, muebles y otros materiales...
  • Página 9 MODELO 605RP Página 9 4. Con un destornillador plano, saque las tapas removibles apropiadas. RANURA DE ENTRADA PARA CABLE DESENGANCHE Si el interruptor no está conectado apropiadamente y hay que cambiar los cables: 1. Cada entrada para cable tiene una ranura de desenganche.
  • Página 10: Operación

    MODEL 605RP Page 10 OPERACIÓN Antes de usar el calentador, asegúrese de que esté instalado ad- ecuadamente, de acuerdo con los pasos de instalación indicados en “PREPARACION” en la página 1.
  • Página 11: Mantenimiento

    MODEL 605RP Page 11 MANTENIMIENTO El usuario puede realizar las siguientes tareas de mantenimiento y limpieza. Todos los demás servicios los debe realizar un técnico autorizado. Si tiene preguntas, consulte a nuestro departamento de servicio al cliente llamando al: 800-558- 1711.
  • Página 12: Piezas De Repuesto

    Ud.puede tener otros derechos, los cuales varían de estado a estado. Esta garantias reemplaza a todas las garantías anteriores.. SERVICO DE GARANTÍA: Para tener derecho al servicio de garantía, Ud. debe (a) Notificar a Broan-NuTone a la dirección o el número de teléfono abajo, (b) indicar el número de modelo y la identifación de la party y (c) describir la naturaleza de cualquier defecto en la producto o parte.