Start the Motor
• Ground the generator. Disconnect all the devices
from the connection panel (A) and double check the
switch and breakers are OFF.
• Make sure the fuel tap (B) is open.
• Set the choke lever (C) into the OFF position.
• Insert the switch key (D) and turn into the START
position.
• Once the machine is ON, turn the switch into the
ON position.
Starting with the jack-line:
• Insert the switch key and turn into open position
(ON).
• Gently pull the jack-line (E) until feeling resistance
in the line. Then pull with force to star the motor.
• Once is ON, set the chole lever (C) into the open
position (ON).
Connecting Devices
• After starting the generator, connect the devices
needed (F) into the terminals in the connection
panel.
CAUTION
If connecting more than one device,
connect first those using a higher current to start.
CAUTION
Verify the devices do not exceed
longer than 30 minutes' the rated current of the
generator and that never exceed the maximum
output load.
• Turn ON the switch and the breakers.
Overload
CAUTION
• If there is an important overload, the
overload protector will turn OFF. It is possible that a
marginal overload will not turn OFF the thermal
protection but will reduce the useful life of the generator.
CAUTION
• If the overload protector is OFF
because a circuit is overloaded, reduce the electric
charge of the circuit and wait a couple of minutes before
restarting the overload protector (G).