Operation; Cleaning And Maintenance; Troubleshooting - NuTone XN50L Guia De Instalacion

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Page 12
WARNING
Before servicing or cleaning unit,
switch power off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.

Operation

To Operate Fan
Use an ON/OFF switch to operate this ventilator.
It is normal for this ventilation fan to take approximately 5
seconds to start running after it is turned on.
To Operate Lights
The light and night light can be operated independently,
using separate on/off switches.

Cleaning and Maintenance

CAUTION
IN ORDER TO PREVENT MOTOR/CONTROL DAMAGE:
DO NOT remove motor plug to stop spinning motor.
Power must be disconnected (see WARNING at top left of
this page) before motor plug is removed or inserted into
control assembly.
To Clean
For quiet and efficient operation, long life and attractive
appearance, remove Grille and vacuum interior of unit
with a dusting brush attachment.
The Motor is permanently lubricated and never needs
oiling. If the motor bearings are making excessive or
unusual noises, replace the Control Assembly and Motor.
To Change Bulbs
Refer to Retrofit Installation
Step 14 (page 11).
1. Carefully insert a small
flathead screwdriver
between the Grille and Lens,
then twist to remove Lens.
2. Purchase two (2) 18W (max.)
type GU24 fluorescent lamps
with Maximum Overall Length
(MOL) of 3.9" (100 mm). Purchase a 4W (max.) C7-type
incandescent night light bulb.
3. Insert bulbs into their sockets. Replace Lens.

Troubleshooting

Symptom: The fan does not run.
• Check for an open fuse or circuit breaker in the
• Check that the two (2) plug-in connections for the Motor
• Check that the Blower Wheel spins freely.
Symptom: The fan runs erratically.
• Check that the Blower Wheel is firmly attached to the
Symptom: The fan seems noisy.
• Check that the back draft damper in the fan's Duct
• Check that the back draft damper in the wall or roof cap
M.O.L.
3.9" (100 mm)
XN50L
XN80L
n
building's service panel.
and the Control are seated firmly in place.
Motor shaft and both spin freely.
Connector pivots freely. Screws used to attach the duct
to the Duct Connector may be preventing the damper
from opening.
pivots freely. These dampers are sometimes mistakenly
painted shut or obstructed by bird and insect debris..