Unit Parts Breakdown; Torch Consumable Parts Selection & Replacement - Forney 325P Manual De Instrucciones

Cortadora de plasma
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Unit Parts Breakdown

Torch Consumable Parts Selection & Replacement
DISCONNECT PRIMARY POWER AT THE SOURCE AND WAIT FOR THE TORCH
TO COOL BEFORE DISASSEMBLING THE TORCH OR TORCH LEADS.
USE ONLY TORCHES AND CONSUMABLES SPECIFIED IN THIS OPERATING
MANUAL.
IT IS EXTREMELY IMPORTANT THAT YOU READ CAREFULLY THESE STRUCTIONS
BEFORE CHOOSING THE CONSUMABLES FOR YOU TORCH. THIS WILL
PREVENT DAMAGES TO YOUR TORCH AND PLASMA SYSTEM.
Plasma torch consumables through the course of normal use will wear and need to be replaced
periodically. Before using the plasma system, you should check your parts for wear and replace if
necessary.
The PIP (Parts-In-Place) design of the torch requires that consumables be installed correctly in order for
the torch to operate. To change the torch consumable parts use the following procedure:
1. Position the torch with the shield cup facing upward to prevent these parts from falling out
when the cup is removed.