Temperature Monitoring; The Antistatic System; Working With The Dust Extractor - Festool CT SYS HEPA Manual De Instrucciones

Ocultar thumbs Ver también para CT SYS HEPA:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Before lifting, check the carrying strap for
proper functionality and put T-loc at dust ex-
tractor into corresponding position.
Adjust the length of the carrying strap at the adjust-
ing tab [4c].
4c
WARNING
Not suitable to vacuum hazardous or toxic sub-
stances or dusts e.g. asbestos.
The filters will not be able to capture all particles
and may exhaust them back into the environment.
CAUTION
Hazardous dust
Damage to the respiratory passage
Always use a filter bag!
 Two cleaning nozzles are stored in the inside of
the dust extractor [5-1].
– Risk of tilting, do not place on sloped areas!
Observe the following instructions:
– Risk of explosion and fire: Do not absorb:
– Sparks or hot dust;
– Combustible or explosive materials (e.g.
magnesium, aluminium, petrol, diluting
agents);
– Aggressive materials (e.g. acid, alkaline solu-
tions, solvents);
– Chemically reactive materials, which lead to
the generation of heat, acids/bases, gases,
Before reaching a critical temperature, the tem-
perature monitor switches off the dust extractor.
 Not possible to switch on: Contact Festool cus-
Friction inside the extraction hose causes static
electricity to develop during extraction. Operating
personnel may receive unpleasant electric shocks
while working. The mobile dust extractor is fitted
with an antistatic system as standard to discharge
any static electricity that may develop. However, al-
ways use the enclosed antistatic extraction hose.

Working with the dust extractor

– Observe all national safety regulations as well as
– Do not lift or transport using a crane hook or lift-
– Always use suitable protective equipment!
– If intact following a visual inspection, work in a dry
– The dust extractor is a stationary system and not

Temperature monitoring

Switch off the dust extractor, allow to cool for
about 5 minutes, then switch on again.
tomer service workshop.

The antistatic system

etc. (e.g. reactive 2-component materials, al-
uminium and water).
the material manufacturer's specifications!
5
5-1
ing gear!
environment according to instructions!
suitable for pulling at the cable and hose. Use
handle [1-4].
13
Tabla de contenido
loading

Tabla de contenido