Idiomas disponibles

Fastening hooks are provided, allowing you to
GB
fasten the hob to tops that are between 20 and 40
mm thick. To ensure the hob is securely fastened
to the top, we recommend you use all the hooks
provided.
Hook fastening diagram
Hooking position
for top H=20 mm
Hooking position
for top H=40 mm
! Use the hooks contained in the "accessory pack"
• Where the hob is not installed over a built-in oven, a
wooden panel must be installed as insulation. This
must be placed at a minimum distance of 20 mm
from the lower part of the hob.
Ventilation
To ensure adequate ventilation, the back panel of the
cabinet must be removed. It is advisable to install the
oven so that it rests on two strips of wood, or on a
completely flat surface with an opening of at least 45 x
14
555 mm
Hooking position
for top H=30 mm
Front
Back
560 mm (see diagrams).
Where a hob is installed above an oven without a
forced ventilation cooling system, adequate
ventilation must be provided inside the cabinet by
means of air holes through which air can pass (see
figure).

Electrical connection

Hobs equipped with a three-pole power supply
cable are designed to operate with alternating
current at the voltage and frequency indicated on
the data plate (this is located on the lower part of the
appliance). The earth wire in the cable has a green
and yellow cover. If the appliance is to be installed
above a built-in electric oven, the electrical
connection of the hob and the oven must be carried
out separately, both for electrical safety purposes
and to make extracting the oven easier.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the
load indicated on the data plate.
The appliance must be directly connected to the
mains using an omnipolar circuit-breaker with a
minimum contact opening of 3 mm installed between
the appliance and the mains. The circuit-breaker
must be suitable for the charge indicated and must
comply with current electrical regulations (the earthing
wire must not be interrupted by the circuit-breaker).
The supply cable must not come into contact with
surfaces with temperatures higher than 50°C.
! The installer must ensure that the correct electrical
connection has been made and that it is compliant
with safety regulations. Before connecting to the
power supply, make sure that: