SWC515 PinMount™ / SWC615 PowerMount™ Weigh Module » Installation
Before You Begin
1
»
Never extend or cut the load cell's
cable length. Always remove the
load cell before welding.
1
Make Sure Locking Plates are Installed
4
»
Use SafeLock™ Centering Washer and SafeLock™ Locking Plate.
2
Tools You Need:
2
- OR -
- OR -
- OR -
5
»
Tank Leg
Anti-Lift Bolt
Sleeve
Tank Foot
Centering Spacer
Locking Plate
Metal Spacer
Weigh Module
Top Plate
Locking Nut, or
Nut with Locking
Download Installation Guide:
Installation Guide is available in:
English, German, Spanish, French,
Italian, Dutch, Portuguese, Swedish,
Danish, Norwegian, Polish, Czech,
Hungarian, Russian, Turkish
www.mt.com/ind-downloads-pinmount
Plan Your Layout
»
Without Stabilizers
With Stabilizers
2L
L
Mounting Optional Pads
Plate
Pad
Plate
Washer
Download Installation Guide:
Installation Guide is available in:
English, German, Spanish, French,
Italian, Dutch, Portuguese, Swedish,
Danish, Norwegian, Polish, Czech,
Hungarian, Russian, Turkish
www.mt.com/ind-downloads-615powermount
Position the Weigh Modules
3
»
Block tank when in
raised position.
Lift tank
1
TANK
Position weigh modules under tank
2
legs according to your layout
Mounting Optional Stabilizer
6
»
1 or 2 stabilizers can be installed.
Use Thread Lock
Compound