Instructions For Plasma Cutter - Elettro CF PLASMA 55 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
Before using this device all people authorized to its use,
repair or inspection, should read the book "Safety rules" and
the "Instruction manual" specific for every machine. Contact
your distributor if you have not understood some instructions.
1 SAFETY DEVICES
This unit is provided with the following safety devices:
Thermic: located on the power transformer windings to avoid
overloads. Signalled by indicator light C on (see pict. 1 - 1a).
Pneumatic: located on the torch feed line to avoid insufficient
air pressure. Signalled by indicator light E (see pict. 1 – 1a).
Electric: located on torch body to avoid dangerous voltages
while replacing nozzle, diffuser, electrode or nozzle holder.
- Do not remove or short-circuit the unit safety devices.
- Only use genuine spares.
- Always replace any damaged part of the unit or torch
with genuine material.
- Only use genuine torches.
- Do not let the unit work without covers. This would be
dangerous for operator and for those who are
surrounding the work area and would prevent the unit
from cooling efficiently.
2 DESCRIPTION OF TECHNICAL SPECIFICATIONS
IEC 974-1
This machine is manufactured according
EN60947-1
to these international standards.
Item and serial number must appear on
ART
any requests concerning the machine.
Three-phase transformer-rectifier.
Drooping characteristic.
6

INSTRUCTIONS FOR PLASMA CUTTER

Plasma arc cutting.
Uo
Secondary no-load voltage.
X
Duty - factor percentage. The duty - factor
expresses the percentage of 10 minutes in
which the welding machine can operate at a
determined current, without over heating.
I
Welding current.
2
U
Secondary voltage with welding current I
2
U
Nominal supply voltage.
1
3~50/60Hz
Three-phase supply 50 or 60Hz.
I
Absorbed current at the corresponding
1
welding current I
IP21
Grade of protection of frame. Grade 1 as a
second number means that this unit is not fit
to work outside under the rain
Fit to work in high - risk areas.
NOTES
In addition, the welding machine has been
designed to work in areas with grade 3 of
pollution (See IEC 664).
3 DESCRIPTION OF UNIT DEVICES (see picture 1, 1a and 2)
A) 230V-0-400V switch.
B) Mains pilot light.
C) Light signalling thermostat.
D) Gauge.
E) Light signalling air pressure is not enough.
F) Torch.
G) Texas connection.
H) Cutting power adjusting knob.
I) Air pressure reducing unit.
L) Mains input cable.
M) Cable pressing device.
N) Fixed adapter (only for item 489).
3.1 ASSEMBLY AND ARRANGEMENT
Unpack the unit and assemble the handle with the supplied
spanner. Place the unit in properly ventilated if possible
undusty room making sure that the air inlet and outlet from
cooling slots are not obstructed.
The machine item 488 is suitable only for ELETTRO CF
torches type P50 and the machine item 489 only for
ELETTRO CF torches type P70. ELETTRO CF does not
assume any responsibility in case that a different kind of
torch is used.
3.2 SETTING AT WORK
The unit must be installed by skilled personnel. All
fittings must be in conformity with the existing rules and
in full compliance with safety regulations.
Connect the air feed to fitting on the air pressure reduction
unit I (pict. 2) making sure that pressure is 88PSI (6bar or
KPaX100) at least with a minimal capacity of 420 CFH (200
litres/min). Should air feed come from a pressure reducing
unit of a compressor or of a centralized plant, the reducing
2.
1,6.
2
Tabla de contenido
loading

Este manual también es adecuado para:

Plasma 70

Tabla de contenido