PROBLEM
Not enough
pressure.
The pressure
washer does not
start up.
Fluctuating
pressure.
The motor stops
suddenly.
CAUSE
•
Water inlet filter is
clogged.
•
Air from the hose
connections is entering
the pump.
•
The nozzle or relief valves
are worn or not the
correct size.
•
The unit is pressurized.
•
Plug is not well connected
or electric socket is
defective.
•
Extension cord is too long
or wire size too small.
•
Main voltage supply is
too low.
•
Thermal safety switch
has tripped.
•
Pump is sucking in air.
•
Clogged nozzle.
•
Valves dirty or worn.
•
Water seals worn.
•
Extension cord is too long
or wire size too small.
•
Thermal safety switch
has tripped due to
overheating.
SOLUTION
•
Clean the water inlet filter.
•
Check that connections and
locking ring are properly
tightened.
•
Contact the Technical Support
Service of Cecotec.
•
Squeeze trigger on gun.
•
Check plug, socket and fuse.
•
Remove extension cord.
•
Check that main supply
matches the voltage stated on
the product's rating label.
•
Switch the device off and allow
it to cool down.
•
Check that hoses and
connections are tight.
•
Clean with the cleaning kit
•
Contact the Technical Support
Service of Cecotec.
•
Contact the Technical Support
Service of Cecotec.
•
Remove extension cord.
•
Check that main supply
matches the voltage stated on
the product's rating label.
HIDROBOOST 1400