INSTALLATION
MOUNT PUMP
Select a dry location (to avoid water intrusion and pump damage) above the
solution tank.
To prevent pump damage in the event of a pump tube leak, never mount the
pump vertically with the pump head up.
DO NOT mount pump directly over an open solution tank. Keep tank covered.
Avoid flooded suction or pump mounted lower than the solution container. Draw
solution from the top of the tank. Pump can run dry without damage. If pump is
installed with a flooded suction, a shut-off valve or other device must be provided
to stop flow to pump during service.
To prevent motor damage, verify with a volt meter that the receptacle voltage
corresponds with the pump voltage.
Plug cord into receptacle and turn the pump on.
continued
USA and Canada 800.683.2378, International 904.641.1666
11
Econ LD