Tool Settings
Parameter description
Hibernation Delay
Set the time the tool will
remain at Sleep temperature
before entering the Hiber-
nation mode. At this time,
the power supply is cut off
and the tip remains at room
temperature.
Temp Adjustment
It provides a more precise
adjustment between the
selected temperature and the
actual one.
14
Recommendations
This function completely
protects the tip from oxida-
tion during long periods of
inactivity while the tool is in
the stand.
Retinning the tip before pla-
cing the tool in the stand also
helps prevent oxidation and
extends the life of the tip.
Set values within ±50°C
(± 90°F) to achieve zero error.
JBC strongly recommends
the use of TID-A or TIA-A
Thermometers to obtain
precise readings.
Warnings
Increasing the default
value will accelerate oxi-
dation and shorten the tip
life.
When the user chan-
ges the cartridge type, the
parameter should be reset to
0°C/F or to the value needed
for this cartridge. E.g. If a
correction of +20°C (+36°F)
is set for the C245966 (thick
type) and then the user
changes the cartridge for a
C245030 (which is thinner)
without resetting, they would
be working at a temperature
of +20°C (+36°F) lower for
the C245030 which does
not need any temperature
adjustment.