Craftsman 919.167630 Manual Del Propietário página 22

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

PROBLEM
Pressure read-
ing on the regu-
lated pressure
gauge drops
when an acces-
sory is used.
Knocking Noise. Possible defect in safety
Compressor is
not supplying
enough air
to operate
accessories.
Regulator knob
has continuous
air leak.
Regulator will
not shut off air
outlet.
Motor will not
run.
1000002924
CAUSE
It is normal for "some"
pressure drop to occur.
valve.
Defective check valve.
Prolonged excessive use of
air.
Compressor is not large
enough for air requirement.
Hole in hose.
Check valve restricted.
Air leaks.
Restricted air intake filter.
Damaged regulator.
Damaged regulator.
Motor overload protection
switch has tripped.
Tank pressure exceeds
pressure switch "cut-in"
pressure.
CORRECTION
If there is an excessive
amount of pressure drop when
the accessory is used, adjust
the regulator following the
instructions in the "Description
of Operation" paragraph in the
Operation section.
NOTE: Adjust the regulated
pressure under flow
conditions (while accessory is
being used).
Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.
Replace check valve.
Decrease amount of air usage.
Check the accessory air
requirement. If it is higher
than the SCFM or pressure
supplied by your air
compressor, you need a
larger compressor.
Check and replace if required.
Replace check valve.
Tighten fittings.
Clean or replace air intake
filter. Do not operate the
air compressor with the fil-
ter removed. Refer to the
"Air Filter" paragraph in the
Maintenance section.
Replace.
Replace.
Refer to "Motor Overload
Protection" under Operation.
If motor overload protection
trips frequently, contact a
Trained Service Technician.
Motor will start automatically
when tank pressure drops
below "cut-in" pressure of
pressure switch.
22- ENG

Capítulos

Tabla de contenido
loading

Tabla de contenido