Installation; Installing/Replacing The Lamps; Operation - EuroLite FL-1200 Manual Del Usuario

Flame-light
Ocultar thumbs Ver también para FL-1200:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTALLATION

Installing/Replacing the lamps

Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need five MR-16 12V/35W GX-5.3 lamps.
During the operation, the lamp reaches temperatures of up to 145° C.
Procedure:
Step 1: If replacing the lamp, remove the old lamp from the lamp-socket.
Step 2: Insert the new MR-16 12V/35W GX-5.3 lamp into the lamp-socket.
Installation
Install the device out of the public area.
Only install the machine on scratch resistant surfaces.
This device is constructed for a standing installation only.

OPERATION

Before starting operation make sure that the silk cannot be drawn into the intake of the ventilation fan. With
the POWER-switch, you can switch the device on and off.
DANGER TO LIFE!
Only install the lamps with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
11/23
51114420_V_1_0_2791.DOC
Tabla de contenido
loading

Tabla de contenido