General Maintenance; Checking The Oil Level - Far Tools GI 1000 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

-
Operating the generator set
a)
When the generator has stabilised its speed (1 min), connect the male
connector(s) into the female connector of the AC generator. Depending on the mo-
del, check that the circuit breaker is engaged. From this moment, you can use your
electrical equipment
- Eco mode
Turn the ECO position (20) to «ON»
It permits to consume less fuel during weak power solicitations (< 500 W)
-
Shutting down the generator set
a)
Disconnect the connectors to allow the motor to run off-load for 1 or 2 min. Set
the on/off switch (13) to «OFF»: the generator shuts down
b)
Close the petrol cock and air intake

CHECKING THE OIL LEVEL

CHECK THE OIL LEVEL EACH TIME THE MOTOR IS STARTED AND EVERY 8 HOURS
OF OPERATION
OIL DRAINING
DRAIN THE MOTOR OIL AFTER THE FIRST 5 HOURS OF OPERATION AND
SUBSEQUENTLY EVERY 50 HOURS
-While the motor is hot, remove the drain plug (1) and allow all the oil to evacuate
into a container.
-After the oil has completely evacuated, put the drain plug (1) back in position.
-Unfasten and remove the filling dipstick cap.
-Replace and refasten the filling dipstick cap on its neck.
-Wipe any trace of oil with a clean cloth.
118035-Manual-A.indd 27
.
.(17) (19)

GENERAL MAINTENANCE

EN
5/10/10 9:36:05