Stid SPECTRE EXTREM Manual De Instalación página 2

Ocultar thumbs Ver también para SPECTRE EXTREM:
Idiomas disponibles

Idiomas disponibles

SPECTRE Module Industry - SME
Frequency Band: 865 - 868 MHz
Frequency Band: 902 - 928 MHz
SME/SLE:
To supply model or to provide V+, V- use only power adaptors with outputs in compliance with ES1 and PS2(LPS per Annex Q of IEC/UL/EN 62368-1) types.
V+, V- musn't exceed 30 Vdc.
Main power supply:
Range +12 Vdc up to +30 Vdc
Consumption:
Typical: 0.6 A under +24 Vdc
SME/SLE-POE+:
Use an IEEE 802.3at.2009-compatible PSE (Power Sourcing Equipment).
Main power supply:
Range +42.5 Vdc to +57 Vdc
If several readers are connected to the PSE, check that each port of the PSE supplies 20W.
Communication:
RS485 (L+ & L-) / RS232 (TD & RD) / Ethernet
Temperature:
-25°C to +60°C / -13°F to +140°F
IP67 level (SME) – IP66 level (SLE)
Protection:
Chip:
EPC1 Gen2 (ISO 18000-63) - 1 to 62 bytes max
I/O:
4 optocoupled inputs and 4 optocoupled outputs
Module LED:
1 red LED: presence of power supply / 1 Green LED activity on Reader / host link
Antenna LED:
7 colors (red, green, blue, orange, purple, turquoise, white) controlled by SSCP commands
Use a multi-conductor shielded twisted pair cable.
Max length RS485:
3 280 ft / 1000 m at 9600 baud (SYT2 AWG24 recommended)
Max length RS232:
49.21 ft / 15 m (SYT2 AWG24 recommended)
Ethernet:
100m, category 5E
▪ Install the module/reader away from computer transmission cables or from power sources (ex: RJ45, sector...).
The disruptions that they can cause can vary according to their radiation power and their proximity.
▪ Use a filtered and regulated power supply.
▪ Antennas connected to different modules/readers may interfere with each other. Move them away from each other.
▪ A power supply which provides 1 A min under +24Vdc is recommended.
If the IN/OUT are powered by the module, use a 2A min under +24Vdc power supply.
▪ Users must not remain within a range of less than, 34 cm / 13.39 in from an antenna for an extended period of time as per EN50364 applicable to this
type of device.
▪ Apart from the hatch the module housings must not be opened.
▪ Before any service operation you must de-energize reader.
▪ Check that the hatch seal is correctly positioned before closing.
▪ Do not remove the caps from the unused RF connectors:
▪ When device is powered by POE & for outdoor use, it must be installed in a restricted access location ( PoE not accessible for ordinary person without use of a
tool).
▪ Any (dis) connection or maintenance work must be made with Power switched OFF.
J16-M12 X-coded:
Ethernet POE
1
2
3
4
5
6
7
8
SPECTRE UHF EXTREM
Installation procedure
SME-W42-A-U04: RS232
SME-W43-A-U04: RS485
SME-W44-A-U04: TCP-IP + POE
SME-W52-A-U04: RS232
SME-W53-A-U04: RS485
SME-W54-A-U04: TCP-IP + POE
Power Supply Characteristics - SME /SLE
Typical: +24 Vdc
Max: 0.8 A under +24 Vdc
Typical: +48 Vdc
Recommended Cables - SME / SLE
Recommendations - SME / SLE
Front View of the Module - SME / SLE
J16 -M12
J17- M12
Ethernet / RS232 / RS485 / IN /OUT CONNECTION - SME / SLE
TX+ / PoE+1
TX- / PoE+1
RX+ / PoE+2
RX- / PoE+2
PoE+2
PoE+2
PoE+1
PoE+1
© STid - 20 PA des Pradeaux FR13850 Gréasque – NI1142X01 - Page 1 sur 12 - Ed. 24/07/2020
UHF SPECTRE EXTREM
Notice d'installation
Frequency Band: 865 - 868 MHz
ERP: 2W
+
Frequency Band: 902 - 928 MHz
EIRP: 4W
+
Characteristics - SME / SLE
J4-M12
Green LED
RF port 1
Red LED
Female / SME
J17-M12 A-coded
1
+Vcc
2
Tx_SME / Rx_Host
3
GND
4
GND
5
Rx_SME / Tx_Host
Male / Host
6
GND
7
L+ / A
8
L- / B
9
+Vcc
10
NC
11
NC
12
NC
UHF SPECTRE EXTREM
Manual de instalación
SPECTRE Reader Industry - SLE
SLE-W42-A-U04: RS232
SLE-W43-A-U04: RS485
SLE-W44-A-U04: TCP-IP + POE
SLE-W52-A-U04: RS232
SLE-W53-A-U04: RS485
SLE-W54-A-U04: TCP-IP + POE
RF port 2
RF port 3
RF port 4
J4-M12 A-coded: IN/OUT
1
+Vcc
2
OUT1
3
IN3
4
V- OPTO
5
IN1
6
GND
7
V+ OPTO
8
OUT4
9
OUT3
10
OUT2
11
IN2
12
IN4
US
FR
ES
+
+
loading