Operation with JT station
1. Placing
2. Heating
Position the suction cup.
Push the button for hot air
heating. The solder melts.
Process Control
Manual mode
Time to stop
T e m p
400 85
Current temperature
400 º C Select
Selected temperature
Power
Access Menu (pess key 2 seconds) & Confirm Selection
You can switch between operating modes (Manual Mode / Profile Mode) by pressing the "increa-
se" and "decrease" keys simultaneously for 2 seconds. (Only when mode profiles is ON)
12
3. Releasing
The component lifts off
automatically.
45 seconds
º
C
A i r %
70%
% Instant power supplied
to heater
Program mode
P r o g r a m 8
º
C
Graph of selected
program
Decrease program
number
Program Options
Edit Program
This option allows you to edit or create a program.
First , you must select the program to edit and then modify the points that make up the program.
Each program is composed of 9 points, each point consisting of 3 parameters:
1. Time (seconds)
2. Temperature (°C / °F)
3. Flow rate (%)
You can delete the last point of the program by selecting "-----" in the time parameter.
It should be taken into account that the regulation range permitted by the station is 150-450°C,
whereby it is not possible to create temperature ramps between room temperature (Toff) and
150°C.
The station can store up to 25 temperature programs.
The first three programs are edited by JBC as an example.
Copy Program
This option allows you to copy a program.
You must select the program source and the program destination (where it will be copied).
Delete Program
This option will allow you to delete a previously selected program.
w w w.jbctools.com
Selected program
T e m p
º
C
380
Current temperature
Air
100%
Selected flow
Time 125s.
Remaining time
Increase program
number
13