Working With Robots; Maintenance - jbc RMSE-C Serie Manual De Usuario

Estación completa de reparación con bomba neumática
Ocultar thumbs Ver también para RMSE-C Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Working with Robots

Manage and monitor the station using a Robotic system.
1. Connect the tool to the station port by means of the CHB-A Converter.
2. Connect your Robot system to the Robot connector (RJ12) of the station.
DB9-RJ12 Adapater available only if necessary (Ref: 0013772).
3. Enable the Robot option in the station settings and the notification will be displayed:
4. Set your Robot's commands according to the Robot Communication Protocol, available on the
website www.jbctools.com/jbcsoftware-menu-115.html.
Robot
Update the station software
1. Download the JBC Update File from
www.jbctools.com/software.html and save
it on a USB flash drive. Preferably one with
no other files.
JBC
Update File
30
CHB-A
Converter
Ref. CHB-A
Control
Unit
RS-232
connection
2. Insert the USB flash drive to the station.
The icon
is diplayed while updating.

Maintenance

Before carrying out maintenance or storage, always allow the equipment to cool.
- Clean the station screen with a glass cleaner
or a damp cloth.
- Use a damp cloth to clean the casing and
the tool. Alcohol can only be used to clean
the metal parts.
- Periodically check that the metal parts of
the tool and stand are clean so that the
station can detect the tool status.
- Maintain tip surface clean and tinned prior
to storage in order to avoid tip oxidation.
Rusty and dirty surfaces reduce heat
transfer to the solder joint.
- Periodically check all cables and tubes.
- Replace a blown fuse as follows:
Fuse holder
1. Pull off the fuse holder and remove the
fuse. If necessary use a tool to lever it off.
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
w w w.jbctools.com
Clean periodically
Fuse
Fuse holder
2. Press the new fuse into the fuse holder
and replace it in the station.
31

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Rmse-1cRmse-2cRmse-9cRmse-c

Tabla de contenido