EN
number of possible causes and the appropriate
solutions are given below:
Air loss
May be caused by a poor seal of a connection.
Check all air connections by wetting them with
a soapy water solution ( Never use the
solution nearby electric connections )
When the tank is empty and being filled. The
user might hear a sisseling sound by the
pressure switch. This is normal and will stop
before the compressor reach a pressure of 1.5
bar
Check if the drain valve ( 11) is closed well
The compressor will not start
If the compressor is difficult to start, check:
whether the voltage of the mains corresponds
to that on the specification plate (fig. 10)
whether electrical extension cables are being
used with a faulty core or length.
whether the operating environment is too cold
(below 0°C).
whether there is electricity supply (plug
properly connected, magneto-thermal fuses
not broken).
The compressor does not shut off
If the compressor does not shut off when the
maximum pressure has been reached, the safety
valve of the tank will be activated. It is necessary
to contact the nearest authorised Support Service
for the repair.
Repairs and servicing should only be
carried out by a qualified technician or
service firm.
Cleaning
Regularly clean the machine housing with a soft
cloth, preferably after each use. Keep the
ventilation slots free from dust and dirt. If the dirt
does not come off use a soft cloth moistened with
soapy water. Never use solvents such as petrol,
alcohol, ammonia water, etc. These solvents may
damage the plastic parts.
Drain the tank
Compressing air will cause water in the tank.
Regularly drain the water from the tank to prevent
tank corrosion (fig 16):
First reduce the pressure in the tank till
aprroxially 2 bar by connecting and activating
an air tool .
8
Then slowly turn the drain valve (11) on the
lower side of the tank open.
The water in the tank will now leak out of the

tank

Take care when compressed air is in the tank
because the water can come out with some force.
Recommended pressure max. 1-2 Bar.
Clean the air filter
It is recommended to disassemble the suction filter
every 50 operating hours and to clean the filter
element by blowing it with compressed air (fig. 15).
It is recommended that the filter element is
replaced at least once a year if the compressor is
working in a clean environment; more often if the
environment in which the compressor is situated is
dusty.
Lubrication
It is recommended to disassemble the suction filter
every 50 operating hours and to clean the filter
element by blowing it with compressed air (fig. 15).
It is recommended that the filter element is
replaced at least once a year if the compressor is
working in a clean environment; more often if the
environment in which the compressor is situated is
dusty. The compressor makes condensed water
which collects in the tank. It is necessary to
remove the condensed water in the tank at least
once a week by opening the drain cock (fig. 16)
under the tank. Take care when compressed air is
in the bottle because the water can come out with
some force. Recommended pressure max. 1-2
Bar.
Faults
Should a fault occur, e.g. after wear of a part,
please contact the service address on the
warranty card. In the back of this manual you find
an exploded view showing the parts that can be
ordered.
Environment
To prevent damage during transport, the appliance
is delivered in a solid packaging which consists
largely of reusable material. Therefore please
make use of options for recycling the packaging.
Faulty and/or discarded electrical or
electronic apparatus have to be collected
at the appropriate recycling locations.
Warranty
The warranty conditions can be found on the
separately enclosed warranty card.