EuroLite NB-100 ICE Manual Del Usuario página 19

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Addressing the Projector
Dipswitches set the DMX addresses.
Controlling:
After having addressed all NB-100 ICE devices, you may now start operating these via your controller.
Important: If start addresses are programmed via dipswitches, then the remote control is de-activated.
DMX-protocol
Channel 1 – Fog Volume
Mode
Volume (%)
0 – 25
10
26 – 50
20
51 – 75
30
76 – 100
40
101 – 125
50
126 – 150
60
151 – 175
70
176 – 200
80
201 – 225
90
226 - 255
100
Channel 2 – Ventilation Volume
Mode
Volume (%)
0 – 25
10
26 – 50
20
51 – 75
30
76 – 100
40
101 – 125
50
126 – 150
60
151 – 175
70
176 – 200
80
201 – 225
90
226 - 255
100
Setting the DMX-
DIP-switch no.
starting address:
Device number
Starting address
& channels
On
Device 1 - channel 1
Off
Off
On
Device 2 - channel 2
Off
On
Device 3 - channel 3
Off
On
Device 4 - channel 4
Off
On
Device 5 - channel 5
Off
1
2
3
4
5
6
16
1
2
4
8
32
19/38
7
8
9
64 128 256
51701982_V_1_0.DOC
Tabla de contenido
loading

Tabla de contenido