DESULPHATION
15.8V
15.8V
15.8V
15.8V
RECOND
Limit:
Max 8h
20016551B MUS 4.3 NG, Manual, Print file 002.indd 9
SOFT START
BULK
0.8A until 12.6V Increasing volt-
age to 14.4V.
0.8A
4.3A until 12.6V Increasing volt-
age to 14.4V.
4.3A
4.3A until 12.6V Increasing volt-
age to 14.7V.
4.3A
4.3A until 12.6V Increasing volt-
age to 14.4V.
4.3A
Max 8h
Max 20h
ABSORPTION
ANALYSE
Declining cur-
Checks if volt-
rent. 14.4V
age drops to
12V
Declining cur-
Checks if volt-
rent. 14.4V
age drops to
12V
Declining cur-
Checks if volt-
rent. 14.7V
age drops to
12V
Declining cur-
Checks if volt-
rent. 14.4V
age drops to
12V
Max 10h
3 minutes
RECOND
FLOAT
13.6V
0.8A
13.6V
4.3A
13.6V
4.3A
Max 15.8V
13.6V
1.5A
4.3A
30 min or 4h
10 days.
depending
Charge cycle
on battery
restarts if volt-
voltage
age drops
PULSE
12.7V–14.4V
0.8–0.4A
12.7V–14.4V
4.3–2A
12.7V–14.7V
4.3–2A
12.7V–14.4V
4.3–2A
Charge cycle
restarts if volt-
age drops
EN • 9
2011-12-02 14:21:22