Circuit Breaker
If the PST-2+6 is connected to an AC outlet where sufficient voltage
is present, the unit should operate properly with the protection OK
indicator lit, after the main power switch is turned to the on position.
If the unit still does not function under these conditions check the
circuit breaker button! It is the round black button adjacent to the
incoming AC cord. If the circuit breaker trips immediately, there may
be too great of a current load placed upon it. Simply disconnect one
product at a time until this no longer happens. If the breaker trips
with no components connected, there may be a wiring defect that
requires Furman service.
Indicators
The Furman PST-2+6 features two indicator LEDs; red "protection
OK" and green "Ground." To indicate proper functioning, both LEDs
should be lit whenever the unit is on.
Protection OK Indicator:
Although Furman's Ground Contamination Free Surge Suppression
rarely requires servicing; nature has a way of occasionally creating
electrical forces that are beyond the capabilities of any transient
voltage surge suppressor device to absorb without some degree of
damage. In the instance that this occurs, the red "Protection OK"
LED indicator with turn off and a warning buzzer will sound an
audible alarm. If this happens, the PST-2+6's surge suppression
circuit is compromised. The unit must be returned to Furman Sound
for repair.