Troubleshooting - HAEGER IM-18S.004B Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Note:
– For hygienic reasons exchange the water in the tank after 24 hours.
– To avoid fungi and bacteria leave the lid open after use.

Troubleshooting

You can solve many common problems easily, saving you the cost of a possible service call. Try the
suggestion below to see if you can solve the problem before calling service centre.
Problem
No function.
Compressor noisy.
Indicator lamps do not
turn on.
Ice cubes are too large
and stick together.
Indicator lamp ADD
WATER is on.
Indicator lamp ICE
FULL and ADD WATER
light up at the same
time.
Specifications
Model
Power Supply
Power / Current
Ice Cube Production
Water Tank Capacity
Ice Storage Capacity
Refrigerant
Net Weight
Dimension (W x D x H) mm
Instructions for use
Possible Cause
No power supplies.
Mains power supply too law.
No power supplies.
Water temperature or
ambient temperature too low.
Water level too low.
Water tray is blocked by ice
cubes.
Suggested Solutions
Check the wall outlet.
Connect the plug properly to the wall
outlet.
Turn the appliance off and check the mains
power supply.
Connect to mains power.
Check fuse.
Appliance defective.
Stop the unit right away.
Restart the unit till the ice in water tray
melts down.
Refill water on tank.
Disconnect from mains power supply.
Remove the ice cubes from the automatic
shovel.
Reconnect and press START button.
IM-18S.004B
220-240V~50Hz
150W / 1.3A
15-18kg/24hr
3.2 L
1500 g
R600a/29g
13.5 kg
375 x 408 x 400
English
5
Tabla de contenido
loading