Slat change­over time
Fabric­stretching time
Moving time
Minimum change­over­time
Invert movement direction
Operating hours up
Operating hours down
Information window
During channel selection in the Information window, the following settings can be made or va­
lues displayed.
Display value
Position value, venetian blind
Position value, slat
Restraint
Lock­out protection
82581813
J:0082581813
0 ms ... 10 sec
300 ms ... 10 s
Basic setting: 0 ms / 300 ms
1 ... 600 sec
Basic setting: 120 s
300 ms ... 10 sec
Basic setting: 1 s
On, Off
Basic setting: Off
0...65535
Basic setting: Current value
0...65535
Basic setting: Current value
Explanations
The position value of the Venetian blind can
be changed.
The position value of the slat can be changed.
Display of forced position status.
Display of the lock­out protection status
9/10
Absolute time for changing­
over Venetian blind slats. The
fabric stretching time can also
be set here for the Awning
operating mode.
Absolute time which the
blind/shutter requires from the
top to the bottom end position.
The entry is essential if scene
or position movements are to
occur.
Minimum interruption time
when changing directions. In­
creasing the minimum chan­
ge­over time will cause less
wear on the motors.
Inverts the activation of the re­
lay outputs. During inverted
operation, the relay outputs
"Up" and "Down" should be
activated in reverse. This is re­
quired, for example, for con­
trolling skylights.
The time is counted during
which the load is physically
switched on (relay contact clo­
sed).
This parameter can be reset to
"0", for example after exchan­
ging the load.
The Reset button is used to
reset the counter to "0". The
device must be programmed
to apply the change.
The time is counted during
which the load is physically
switched on (relay contact clo­
sed).
This parameter can be reset to
"0", for example after exchan­
ging the load.
The Reset button is used to
reset the counter to "0". The
device must be programmed
to apply the change.