eNet
Actuador vía radio persianas, carril DIN
Local Operation
Transmission of blind/shutter
position > 10%
Behaviour on voltage return
Configured venetian blind po
sition
Configured slat position
Behaviour after the end of the
disabling function
Priority, lockout protection
Priority, restraint
Priority, wind alarm
Priority, sun protection
Priority, twilight
82581813
J:0082581813
On, Off
Basic setting: On
On, Off
Basic setting: Off
No change
Configured value
Basic setting: No change
0 ... 100 %
Basic setting: 0 %
0 ... 100 %
Basic setting: 0 %
no change
Last value
Down
up
Basic setting: No change
0...4
Basic setting: 1
0...4
Basic setting: 2
0...4
Basic setting: 3
0...4
Basic setting: 0
0...4
Basic setting: 0
8/10
Blocks the output for operation
using the Prog button.
The current position of the
blind/shutter is always trans
mitted when the blind/shutter
comes to a stop. This parame
ter makes it possible to specify
that, during travel, the position
is saved when the blind/shut
ter position changes by more
than 10%. The saved value
can then be polled from the
eNet server.
Defines the behaviour of the
output after voltage return.
RMD design: Bus voltage re
turn
If the value "Configured posi
tion" is entered for the para
meter "Behaviour after voltage
return", then the blind/shutter
position set here is approa
ched.
If the value "Configured posi
tion" is entered for the para
meter "Behaviour after voltage
return", then the slat position
set here is approached.
Behaviour of the output when
a block is removed.
Specifies the priority for reca
lling and removing a scene of
type Lockout protection for
the channel.
Specifies the priority for reca
lling and removing a scene of
type Forced position for the
channel.
Specifies the priority for reca
lling and removing a scene of
type Wind alarm for the chan
nel.
Specifies the priority for reca
lling and removing a scene of
type Sun protection for the
channel.
Specifies the priority for reca
lling and removing a scene of
type Twilight for the channel.
12.03.2014