AQUALUX 104274 Manual De Instalación Y De Utilización página 16

Ocultar thumbs Ver también para 104274:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Model
Differential protection
(mA) to install
Circuit breaker (A) to
install
2
Power cable (mm
)
2
Signal cable (mm
)
Conditions:
Maximum length of the power cable: 10 m.
If the power cable is ≥10m, the diameter must be increased.
The signal cable can be extended to 50m.
The heat pump must not operate if the filter is stopped. This function is performed by a
built-in flow switch. Check that the pump flow is sufficient for the switch to work.
- LINK function :
This function is used to force the operation of the pump in order to achieve the desired temperature. It
requires additional wiring (2 wires on the clock contact). To operate the filter will be placed in automatic
mode (on clock)
NOTPACAQX - ind S – 0315
104274
104275
30
30
10
10
3×2.5
3×2.5
3×0.5
3×0.5
104276
105417
30
30
16
20
3×4
3x6
3×0.5
3x0.5
15/41
105418
104279
30
30
6
10
5x2.5
5x4
3x0.5
3x0.5
Tabla de contenido
loading

Este manual también es adecuado para:

104275104276105417105418104279

Tabla de contenido