Always disconnect the appliance from the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
Our
burners
do
adjustment.
10) TAPS
"Reduced rate" adjustment
- Switch on the burner and turn the relative knob
to the "Reduced rate" position (small flame
fig.1).
- Remove knob "M" (fig. 14) of the tap, which is
simply pressed on to its rod.
- Insert a small screwdriver "D" into hole "C" (fig.
14) and turn the throttle screw to the right or left
until the burner flame has been adequately
regulated to the "Reduced rate" position.
ADJUSTMENTS
not
require
primary
- Check that the flame does not go out when the
knob is sharply switched from the "Full on" to the
"Reduced rate" position.
air
It is understood that only burners operating with
G20 gas should be subjected to the above
mentioned adjustments. The screw must be fully
locked when the burners operate with G30 or
G31 (turn clockwise).