Backlight Yes
Laser sight switchable Yes
Max/Min/Avg./∆T Yes
Auto-measuring Yes
10 point memory Yes
Audio alarm Yes
Battery type 9V, IEC6F22, NEDA 1604
Dimensions 6.69" x 5.23" x 1.71" (170 x 133 x 45 mm)
Weight 187g approx
Accessories 9V battery, instruction manual, carrying
4. OPERATION OF INSTRUMENT

4.1 Quick start

To measure a temperature, point the unit at the target you want to
measure, pull the trigger and hold on till the end of shot. In SCAN
mode, the LCD displays either the current temperature in celsius or
fahrenheit. The unit will HOLD the last reading for about 6 seconds
after the trigger is released, the word HOLD appears. Be sure to
consider the target area inside the angle of vision of this instrument.
The single spot of laser is used for aiming only.

4.2 Unit diagram

1. Display screen.
2. Laser sighting.
3. Measuring window.
4. Measuring trigger.
5. Battery and cover.
6. Scan/Hold/Auto mode indication.
7. Laser ON/OFF indication.
8. Data Max/Min/Ave/∆T.
9. Emissivity/High alarm/Low alarm adjustment indication.
10. Down value button and Up value button.
11. Function button.
12. Data memory indication.
13. °C / °F unit indication.
14. Temperature indication.
15. Low battery.
10