INSTALLATION REQUIREMENTS
LOCATION REQUIREMENTS
Keep flammable materials and vapors, such as gasoline, away from
appliance.
Failure to do so can result in death, explosion or fire.
To ensure proper ventilation for your ice machine, the front of the unit must
be completely unobstructed.
When installing the ice machine under a counter, follow the recommended
spacing dimensions shown in the "Installation Clearances" section. Allow
at least 3-7/8" (9.8 cm) clearance at rear, and 3/8" (1.0 cm) at top and 3/16"
(0.5 cm) at sides for proper air circulation.
The installation should allow the ice machine to be pulled forward for
servicing, if necessary.
Choose a well ventilated area with normal operating temperatures above
50°F (10°C) and below 100°F (38°C). Normal operating water temperature
should be between 41°F (5°C) and 90°F (32°C). Operation of the ice machine
for extended periods outside of these normal temperature ranges may
affect production capacity.
The ice machine should not be located next to ovens, grills or other high
heat sources.
The ice machine MUST be installed in an area protected from the elements,
such as wind, rain, water spray or drips.
The ice machine should be located on a firm and level surface. It is
important for the ice machine to be leveled in order to work properly. If
needed, you can adjust the height of the ice machine by turning the feet.
See the "Leveling the Ice machine" section.
• Do not install the ice machine where the temperature will go below
50°F (10°C) because it will not run often enough to maintain proper
temperatures.
• Do not install the ice machine where the temperature will go above
100°F (38°C) because it will not perform properly.
• Install it on a floor strong enough to support it fully loaded.
• Do not install the ice machine in a location exposed to water (rain,
etc.) or direct sunlight.
49-60811
WARNING
Explosion and Fire Hazard
7