INSTALLER/CONFIGURATION MENU
Menu
Press
Reference
Key
Number
1
and
and
2
and
3
and
4
and
5
and
6
and
7
and
8
and
9
and
and
10
and
4) Select Compressor Lockout CL OFF or ON - Selecting
CL On will cause the thermostat to wait 5 minutes between
cooling cycles. This is intended to help protect the
compressor from short cycling. Some newer compressors
already have a time delay built in and do not require this
feature. Your compressor manufacturer can tell you if the
lockout feature is already present in their system. When the
thermostat compressor time delay occurs, it will fl ash the
setpoint for up to fi ve minutes.
5) Select Backlight Display - The display backlight improves
display contrast in low lighting conditions. When the "C"
terminal is connected, selecting backlight CdL On will keep
the light on continuously. Select backlight OFF will turn the
light on momentarily when any key is pressed. When the
"C" terminal is not connected, regardless of the backlight
selection, the light will be on momentarily when any key is
pressed.
6) Select Temperature Display Adjustment 4 LO to 4 HI -
Allows you to adjust the room temperature display up to 4°
higher or lower. Your thermostat was accurately calibrated
at the factory but you have the option to change the display
temperature to match your previous thermostat. The
current or adjusted room temperature will be displayed on
the display.
All manuals and user guides at all-guides.com
Confi guration Menu
Displayed
Press
(Factory
to select
Default)
from listed op-
tions
CS
On
(OFF)
CS
1, 2, 3, 4, 5, 6
(3)
CR HE-PU
SL
(FA)
CR Aux
SL
(FA)
CL
On
(OFF)
L
OFF
(On)
Temp
4 LO to
(0 HI)
4 HI
o
F
o
C
FH
OFF
(On)
Change Filter
On
(OFF)
Change Filter
25 to 1975
(200 h)
5
Comments
or
Select Cool Savings Feature On or OFF
If CS selected On, selects Cool Savings value
Select Adjustable Anticipation, cycle rate, Heat
Pump, Heat and Cool
Select Adjustable Anticipation, cycle rate,
Heat Pump Aux Stage
Select Compressor lockout OFF or On
Select Display Light On or OFF
Select temperature display adjustment higher
or lower
Select
o
F /
o
C Display (temperature units in
Fahrenheit or Celsius)
Select fast second stage On or OFF
Select fi lter replacement indicator OFF or On
If Change Filter selected On, selects time inter-
val for Change Filter Indicator.
(in 25 hour increments)
Returns to normal operation
7) Select F° or C° Readout - Changes the display readout to
Celsius or Fahrenheit as required.
8) Select Fast Second Stage ON or OFF - (Heat Pump Only)
In the HEAT mode, with the Fast Heat feature enabled (FH
Heat On), if the temperature is manually raised by 3°F (2°C)
or more above the actual temperature using the
second stage will energize immediately. With FH OFF, the
thermostat will determine the optimum time (approximately
0 to 30 minutes) to use Auxiliary/Second stage heat in
addition to the Heat Pump.
9) Select Filter Replacement Reminder and Set Run Time
Select the "Change Filter" reminder On or OFF. If selected
On, press
and
1975 hours in 25 hour increments. In a typical application,
200 hours (default) of run time is approximately 30 days.
After the selected time of blower operation, the thermostat
will display "Change Filter" as a reminder to change or
clean your air fi lter. When "Change Filter" is displayed,
press the
and
restart the time to the next fi lter change. A selection of OFF
will cancel this feature.
to select the time period from 25 to
button to clear the display and
, the