This product is a detector designed to identify gas leaks (natural gas, LPG and coal gas).

PRODUCT DESCRIPTION

Gas detector
MAIN FEATURES OF THE GAS DETECTOR
- Sensor with high reliability
- Automatic reset after alarm
- Detected gas: natural gas, LPG (liquefied petroleum gas) and coal gas
- Use only indoor, wall mounting
TECHNICAL SPECIFICATIONS OF THE GAS DETECTOR
Supply voltage
Output voltage for solenoid valve
Stand-by consumption
Alarm consumption
Maximum consumption
Sensor priming time
Sound intensity
Alarm level
Gas density alarm level
Alarm indicator
Error indicator
Usage temperature
Dimensions

INSTALLATION INSTRUCTIONS

1. First identify if the gas from the source is heavier or lighter than air. Gases heavier than air: LPG. Gases
lighter than air: natural gas, methane gas, etc.
2. Depending on the weight of the gas, choose the correct location of the gas detector. If the gas is heavier than
the air, position the gas detector at a height of 0.3 - 1.0 m from the floor, within a radius of max. 1.5 m from gas
Test button
Alarm LED
State LED
3
230V
9 - 12V (impuls)
≤ 90mA
≤ 100mA
3W (@ 230V)
about 180 seconds
≥ 85dB/m
20% LEL (Lower Explosive Limit)
0.1% - 0.5%
Flashing red LED
Red LED and extended sound
-26°C ~ +80°C
115 x 72 x 41 mm