Power requirements Part 2
Power cables
The usable cable thickness and length depend on the power situation on the
job site.
General rule: The shorter and thicker the cable, the better.
Recommendations cable thickness:
- for countries with 230 volts nominal voltage: 3 x 1.5 mm
- for countries with 110 volts / 120 volts nominal voltage: 12 gauge cable
(3 x 2.5 mm
Use only cables appropriate for this application. Check the cables
regularly for damage.
Outdoors, use only extension cables approved and marked for this
purpose.

Start-up

The induction welding tool is delivered ready for operation ex-works.
The country-specific regulations must be observed.
)
2
After opening the container, the body of the unit
can be carefully lifted out. Then the handle of the
tool (see overview) is removed from the transport
box and carefully inserted into the tool.
2.
1.
5.
4.
3.
1. Use fixing screw to secure the push-fit
connection.
Ensure that the connection is correctly
made.
2. Adjust the handle to an ergonomic
working height. For this purpose,
release the clamping lever at the upright
and adjust the height. Re-tighten the
clamping lever.
3. Connect the tool to a suitable power
source.
- the cable should not be too long
- suitable conductor cross section
- unroll extension cable
4. Operate mains switch to turn unit on.
5. The display shows the input screen.
2
37